PKA-A36FAL (HP)
Mr. Slim Split-ductless: PK-Series Wall-Mounted A/C and Heat Pumps |
|
|
P-series Features
- New hard-wired, multi-lingual remote controller (PAR-21MAA) displays: Fault codes for both indoor and outdoor units, phone number of service contractor and critical unit operating data for service technician
- Wireless Controller available (FAL models)
- Pulse Wave Modulation (PVM) Vector Wave Eco Inverter (all models)
- Outdoor unit sound level reduced by 4 to 8 dB(A)
- Anti-corrosion model now available (-BS model)
- The inverter models perform well in cooling mode even with outdoor temperatures as low as 0°F
- Units interface with Lossnay PZ-41SLB-E controller for ventilation control
- Outdoor unit cabinets meet or exceed Florida "Hurricane" code for high wind load conditions
|
Specifications |
|
Application: |
Heat Pump |
|
BTU Cooling: |
35,000 |
|
BTU Heating: |
37,000 |
|
Mounting Location: |
Wall-mounted |
|
SEER: |
13.1 |
|
HSPF: |
8.3 |
|

|
|
Indoor Unit: |
PKA-A36FA/FL |
|
Indoor Input Power: (V, PH, Hz) |
208/230, 1 Phase , 60 Hz |
|
Indoor Dimensions: (In. HxWxD) |
13-3/8 x 66-1/8 x 9-1/4 |
|
Indoor Weight: (Lbs.) |
62 |
|
Airflow Dry: (CFM) |
780-990 |
|
Airflow Wet: (CFM) |
700-890 |
|
Indoor Sound Level: (dBA) |
46/49 (Lo/Hi) |
|

|
|
Outdoor Unit: |
PUZ-A36NHA |
|
Outdoor Input Power: (V, PH, Hz) |
208/230, 1 Phase , 60 Hz |
|
Outdoor Dimensions: (In. HxWxD) |
37-1/8 x 37-13/32 x 13 |
|
Outdoor Weight: (Lbs.) |
165 |
|
Outdoor Sound Level: (dBA) |
48/50 (Cooling/Heating) |
|

|
|
Pipe Size (Liquid): (In.) |
3/8 |
|
Pipe Size (Gas): (In.) |
5/8 |
|
Indoor Connection Method: |
FLARE |
|
Outdoor Connection Method: |
FLARE |
|
Limited Warranty: 6-year on compressor. 1-year on parts. Specifications are subject to change without notice. | |
|